|
The ultrasonic control
Defectoscope:
- On the basis of the modernized hardware it is prepared for a batch production new base defectoscope general purpose
UZD - 2М
- removed from manufacture UZD - 2-FERTA
- electric parameters Are improved, is reduced power consumption
- software Is modernized
- procedure of the control Was facilitated, due to a new design of gauges
- dimensions defectoscope Have decreased
Depth-gauges cracks:
- the hardware and the software Are modernized
- reduction of overall dimensions Is possible
Another:
- research works on a theme Are carried out(spent):
- " Research of an opportunity of exact measurement of intensity of rails "
- " Research of an opportunity of definition of defects of a surface of rollers by a EMA-METHOD "
- accumulation an operational experience with color liquid crystal (LCD) screens
eddy current control
Defectoscope:
VD-2-1ND
- electric parameters Are improved, is reduced power consumption
- software Is modernized
- reduction of dimensions of the electronic block Is possible
Another
- work on preparation for a batch production new small-sized eddy current defectoscope with gauges of static type Is carried out.
- research works on a theme Are carried out: " Research of an opportunity of definition of defects of a surface of rollers eddy current dynamic method"
temperature control
General purpose devices:
- development of the multipurpose calibrator of temperatures which will allow to make checking and calibration of means of measurement of temperatures comes to an end.
- secondary electronic device VEP-PTS-10-100
- intended for measurement of temperature Is prepared for release, including at realization testing (calibration) works.
specialized thermometers:
Thermometer TGD-1:
- the software (allows to enter amendments to the measured temperature) that allows more precisely standardize the device Is modernized
- miniaturization of the hardware (an opportunity of replacement by more compact case) Is made
- it Is reduced power consumption
Thermometer TGD - 2 (2M):
- software Is modernized
- it Is reduced power consumption
- opportunity of equipment Is stipulated by other type of the gauge
Thermometer TE - 3k (3kM):
- opportunity of use of thermocouples Is added
- software Is modernized
- Hardware is prepared for transition to independent power supplies
Measurement of thickness of coverings
thickness gauge:
Prepares for release thickness gauge for the control of a chromic covering
Planned parameters:
- thickness of a controllable covering: 0-200 microns;
- ПError of measurement of thickness (from the top value) should not exceed 5 %;
- Time of one measurement should not exceed 10 sec;
- Feed of the device should be carried out from a network of an alternating current by frequency 50 Hz and a voltage 220 +-10 V;
- Time of an establishment of an operating conditions of the device in normal conditions should not exceed 15 minutes;
- Weight of the device should not exceed 15 kg;
- Weight of the device should not exceed 15 kg;
|